Assessment Year | 2025 |
---|---|
Principal Product | Lateral Flow, OTC & POC Test Kits |
NAICS | 325413: In-Vitro Diagnostic Substance Manufacturing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $50 M to 100M |
# of Employees | 25 |
Plant Area |
27,000
ft2
|
Annual Production | 221,618
pieces
|
Production Hrs. Annual | 4,950
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,599 | 221,166 |
kWh
|
$0.34 |
Electricity Demand | $44,409 | 826 |
kW-mo/yr
|
$53.74 |
TOTAL YEARLY COSTS | $120,008 | |||
RECOMMENDED SAVINGS* | $91,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $43,986 | $59,050 |
$43,986
128,690
kWh
|
- | |
02 | 2.3141: Use battery storage for demand control | $22,813 | $1,191 |
$(-2,016.9)
(-5,901)
kWh
|
$24,830
-
kW-mo/yr
|
|
03 | 2.7233: Use properly designed and sized hvac equipment | $10,792 | $133,100 |
$10,792
31,573
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,402 | $4,350 |
$1,153
3,373
kWh
|
$249
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,718 | - |
$2,718
7,953
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,337 | $2,362 |
$2,060
6,027
kWh
|
$1,277
-
kW-mo/yr
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,175 | $5,179 |
$2,175
6,363
kWh
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $3,908 | $11,010 |
$684
2,000
kWh
|
$3,224
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $91,131 | $216,242 |
$61,551
180,078
kWh
|
$29,580
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs