Assessment Year | 2025 |
---|---|
Principal Product | Furniture |
NAICS | 337127: Institutional Furniture Manufacturing |
SIC | 2599: Furniture and Fixtures, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 44 |
Plant Area |
32,000
ft2
|
Annual Production | 60
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,097 | 320,430 |
kWh
|
$0.12 |
Electricity Demand | $65,480 | 2,178 |
kW-mo/yr
|
$30.06 |
Electricity Fees | $2,576 | - |
|
- |
TOTAL YEARLY COSTS | $107,153 | |||
RECOMMENDED SAVINGS* | $42,778 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $30,558 | $134,423 |
$14,954
122,570
kWh
|
$15,605
-
kW-mo/yr
|
|
02 | 2.3141: Use battery storage for demand control | $5,044 | $470 |
$(-439.2)
(-3,600)
kWh
|
$5,483
-
kW-mo/yr
|
|
03 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $1,711 | $6,733 |
$1,711
14,022
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $161 | $932 |
$122
998
kWh
|
$40
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $60 | - |
$60
489
kWh
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,220 | $3,314 |
$875
7,161
kWh
|
$1,345
-
kW-mo/yr
|
|
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,896 | $9,455 |
$1,593
13,050
kWh
|
$303
-
kW-mo/yr
|
|
08 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $669 | $511 |
$669
5,480
kWh
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $459 | $1,842 |
$459
3,762
kWh
|
- | |
TOTAL RECOMMENDED | $42,778 | $157,680 |
$20,002
163,932
kWh
|
$22,776
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs