Assessment Year | 2025 |
---|---|
Principal Product | Steel Tubing |
NAICS | 339112: Surgical and Medical Instrument Manufacturing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 157 |
Plant Area |
76,319
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $359,826 | 1,848,653 |
kWh
|
$0.19 | |
Electricity Demand | $184,993 | 3,700 |
kW-mo/yr
|
$50.00 | |
Electricity Fees | $5,150 | - |
|
- | |
Natural Gas | $55,113 | 4,695 |
MMBtu
|
$11.74 | |
Waste Disposal Costs | |||||
Other Liquid (haz) | $243,039 | 426,384 |
gal
|
$0.57 | |
TOTAL YEARLY COSTS | $848,121 | ||||
RECOMMENDED SAVINGS* | $798,946 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $564,124 | $638,912 |
$270,148
1,388,220
kWh
|
$293,976
-
kW-mo/yr
|
- | - | |
02 | 2.3141: Use battery storage for demand control | $82,562 | $4,772 |
$(-9,948.8)
(-51,125)
kWh
|
$92,511
-
kW-mo/yr
|
- | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $3,786 | $6,845 | - | - |
$3,786
-
MMBtu
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,835 | $3,044 |
$4,291
22,052
kWh
|
$1,544
-
kW-mo/yr
|
- | - | |
05 | 4.212: Adopt in-house material generation | $107,677 | $47,756 |
$(-69,965.0)
(-359,535)
kWh
|
$(-33,570.0)
-
kW-mo/yr
|
- |
$211,212
-
gal
|
|
06 | 2.1221: Replace obsolete burners with more efficient ones | $15,250 | $16,600 | - | - |
$15,250
-
MMBtu
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,187 | $1,186 |
$873
4,485
kWh
|
$314
-
kW-mo/yr
|
- | - | |
08 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $16,147 | $6,200 |
$16,147
82,974
kWh
|
- | - | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,377 | $250 |
$2,377
12,217
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $798,946 | $725,565 |
$213,922
1,099,288
kWh
|
$354,775
-
kW-mo/yr
|
$19,037
-
MMBtu
|
$211,212
-
gal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs