Assessment Year | 2001 |
---|---|
Principal Product | Plastic bottle caps |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
83,000
ft2
|
Annual Production | 1,320,000,000
pieces
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $250,171 | 6,134,850 |
kWh
|
$0.041 |
Electricity Demand | $103,456 | 11,486 |
kW-mo/yr
|
$9.01 |
Electricity Fees | $36,535 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,314 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,767 | $11,030 |
$2,119
49,722
kWh
|
$648
-
kW-mo/yr
|
- | |
02 | 2.7145: Install skylights | $2,099 | $11,395 |
$2,099
44,154
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $154 | $375 |
$88
1,856
kWh
|
$66
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,334 | $90 |
$2,320
54,435
kWh
|
$1,014
-
kW-mo/yr
|
- | |
05 | 3.6192: Use a less expensive method of waste removal | $960 | $60 | - | - | $960 | |
TOTAL RECOMMENDED | $9,314 | $22,950 |
$6,626
150,167
kWh
|
$1,728
-
kW-mo/yr
|
$960 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs