Assessment Year | 2024 |
---|---|
Principal Product | Plastic Bottles |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
292,000
ft2
|
Annual Production | 884,000,000
pieces
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,265,763 | 32,575,063 |
kWh
|
$0.13 |
Electricity Demand | $1,234,495 | 68,496 |
kW-mo/yr
|
$18.02 |
Natural Gas | $44,809 | 2,394 |
MMBtu
|
$18.72 |
TOTAL YEARLY COSTS | $5,545,067 | |||
RECOMMENDED SAVINGS* | $802,666 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $150,247 | $333,540 |
$94,937
724,710
kWh
|
$55,310
-
kW-mo/yr
|
- | |
02 | 2.3141: Use battery storage for demand control | $48,096 | - |
$(-12,091.0)
(-92,295)
kWh
|
$60,187
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $86,343 | $34,702 |
$71,599
546,559
kWh
|
$14,146
-
kW-mo/yr
|
$598 | |
04 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $78,160 | $16,180 |
$65,528
500,217
kWh
|
$12,632
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,955 | $2,109 |
$2,398
18,303
kWh
|
$557
-
kW-mo/yr
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,742 | $3,181 |
$4,815
36,752
kWh
|
$927
-
kW-mo/yr
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $86,038 | $57,435 |
$72,140
550,688
kWh
|
$13,898
-
kW-mo/yr
|
- | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $42,562 | - |
$42,562
324,901
kWh
|
- | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,401 | $2,880 |
$3,691
28,168
kWh
|
$711
-
kW-mo/yr
|
- | |
10 | 2.4239: Eliminate or reduce compressed air usage | $2,080 | $3,360 |
$2,080
15,879
kWh
|
- | - | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $53,887 | $3,345 |
$53,887
411,350
kWh
|
- | - | |
12 | 2.4231: Reduce the pressure of compressed air to the minimum required | $56,412 | $3,345 |
$56,412
430,629
kWh
|
- | - | |
13 | 2.4221: Install compressor air intakes in coolest locations | $55,674 | $3,278 |
$46,680
356,339
kWh
|
$8,993
-
kW-mo/yr
|
- | |
14 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $130,069 | $201,000 |
$93,372
712,760
kWh
|
$36,697
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $802,666 | $664,355 |
$598,009
4,564,960
kWh
|
$204,059
-
kW-mo/yr
|
$598 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |