Assessment Year | 2024 |
---|---|
Principal Product | Automated Microelectronic Assembly Machines |
NAICS | 333242: Semiconductor Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
67,528
ft2
|
Annual Production | 45
units
|
Production Hrs. Annual | 4,335
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $275,767 | 875,919 |
kWh
|
$0.31 |
Electricity Demand | $185,991 | 2,351 |
kW-mo/yr
|
$79.11 |
Electricity Fees | $(-152,031.0) | - |
|
- |
Natural Gas | $16,783 | 1,010 |
MMBtu
|
$16.62 |
TOTAL YEARLY COSTS | $326,510 | |||
RECOMMENDED SAVINGS* | $119,229 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,846 | $1,355 |
$1,083
3,440
kWh
|
$763
-
kW-mo/yr
|
- | |
02 | 2.4224: Upgrade controls on compressors | $51,545 | $70,429 |
$31,833
101,120
kWh
|
$19,712
-
kW-mo/yr
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $13,069 | $20,212 | - |
$13,069
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $12,410 | $7,109 |
$12,410
39,423
kWh
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,314 | $4,469 |
$6,639
21,088
kWh
|
$4,675
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,573 | $12,716 |
$15,142
48,101
kWh
|
$10,339
-
kW-mo/yr
|
$92 | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,472 | $2,019 |
$2,325
7,387
kWh
|
$1,147
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $119,229 | $118,309 |
$69,432
220,559
kWh
|
$49,705
-
kW-mo/yr
|
$92 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs