Assessment Year 2023
Principal Product Metal Doors and Windows
NAICS 332321: Metal Window and Door Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $10
M
to 50
M
# of Employees 80
Plant Area 40,000
ft2
Annual Production 100,000
units
Production Hrs. Annual 4,250
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $96,909 1,061,490
kWh
Electricity Demand $27,256 3,233
kW-mo/yr
Electricity Fees $5,614 -
Natural Gas $10,011 363
MMBtu
Waste Disposal Costs
Other Liquid (haz) $62,110 898
gal
TOTAL YEARLY COSTS $201,900
RECOMMENDED SAVINGS* $75,535 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Personnel Changes Savings
01 2.4223: Install direct acting units in place of compressed air pressure system in safety system $1,793 $2,300 $1,793
19,644
kWh
- - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,958 $14,573 $2,193
24,016
kWh
$730
-
kW-mo/yr
- $35
03 3.1121: Use more efficient adhesive applicators $14,334 $2,200 - - $14,334
-
gal
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,070 $500 $1,070
11,724
kWh
- - -
05 2.9114: Use solar heat to make electricty $44,733 $141,268 $32,594
357,000
kWh
$12,139
-
kW-mo/yr
- -
06 2.3141: Use battery storage for demand control $4,384 - $(-4,521.0)
(-49,518)
kWh
$8,905
-
kW-mo/yr
- -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $325 $847 $255
2,787
kWh
$71
-
kW-mo/yr
- -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,872 $2,290 $1,389
15,218
kWh
$483
-
kW-mo/yr
- -
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,066 $5,607 $3,184
34,869
kWh
$882
-
kW-mo/yr
- -
TOTAL RECOMMENDED $75,535 $169,585 $37,956
415,740
kWh
$23,210
-
kW-mo/yr
$14,334
-
gal
$35
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs