| Assessment Year | 2001 |
|---|---|
| Principal Product | Crystals and oscillators |
| NAICS |
n/a
|
| SIC | 3679: Electronic Components, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 332 |
| Plant Area |
52,000
ft2
|
| Annual Production | 2,500,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $160,182 | 2,236,800 |
kWh
|
$0.072 |
| Electricity Demand | $39,788 | 5,020 |
kW-mo/yr
|
$7.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $133,462 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $72,554 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $7,803 | $7,764 |
$7,803
62,899
kWh
|
- | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $5,179 | $208 |
$5,179
50,170
kWh
|
- | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $34,167 | $13 |
$34,167
474,552
kWh
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $8,070 | $312 |
$8,070
92,102
kWh
|
- | |
| 05 | 2.7221: Lower temperature during the winter season and vice-versa | $12,698 | $13 |
$12,698
176,359
kWh
|
- | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $1,572 | $208 |
$1,572
15,226
kWh
|
- | |
| 07 | 2.7221: Lower temperature during the winter season and vice-versa | $3,065 | $13 |
$3,065
42,567
kWh
|
- | |
| 08 | 4.122: Develop standard procedures to improve internal yields | $60,908 | $5,100 | - | $60,908 | |
| TOTAL RECOMMENDED | $133,462 | $13,631 |
$72,554
913,875
kWh
|
$60,908 | ||
| TOTAL IMPLEMENTED | $72,554 | $8,531 |
$72,554
913,875
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs