Assessment Year | 2023 |
---|---|
Principal Product | Aluminum Castings |
NAICS | 331524: Aluminum Foundries (except Die-Casting) |
SIC | 3365: Aluminum Foundries |
Sales Range | $10 M to 50M |
# of Employees | 64 |
Plant Area |
25,000
ft2
|
Annual Production | 36,000
units
|
Production Hrs. Annual | 2,431
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,743 | 508,766 |
kWh
|
$0.14 |
Electricity Demand | $84,606 | 1,728 |
kW-mo/yr
|
$48.96 |
Electricity Fees | $2,349 | - |
|
- |
Natural Gas | $223,032 | 16,038 |
MMBtu
|
$13.91 |
TOTAL YEARLY COSTS | $379,730 | |||
RECOMMENDED SAVINGS* | $162,526 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4224: Upgrade controls on compressors | $616 | $100 |
$616
4,493
kWh
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $566 | $1,200 |
$213
1,552
kWh
|
$353
-
kW-mo/yr
|
- | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $41,916 | $76,410 | - | - | - |
$41,916
-
MMBtu
|
|
04 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $85,551 | $277,200 |
$37,995
277,134
kWh
|
$70,502
-
kW-mo/yr
|
$(-5,543.0) |
$(-17,403.0)
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $424 | $1,176 |
$184
1,345
kWh
|
$230
-
kW-mo/yr
|
$10 | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,102 | $7,882 |
$790
5,760
kWh
|
$1,312
-
kW-mo/yr
|
- | - | |
07 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $2,044 | $8,803 |
$2,044
14,906
kWh
|
- | - | - | |
08 | 2.4226: Use / purchase optimum sized compressor | $936 | $3,415 |
$936
6,826
kWh
|
- | - | - | |
09 | 2.4322: Use or replace with energy efficient substitutes | $27,630 | $115,136 | - | - | - |
$27,630
-
MMBtu
|
|
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $741 | $3,554 |
$212
1,554
kWh
|
$529
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $162,526 | $494,876 |
$42,990
313,570
kWh
|
$72,926
-
kW-mo/yr
|
$(-5,533.0) |
$52,143
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs