| Assessment Year | 2023 |
|---|---|
| Principal Product | Dripline, Gardening Tubing |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 43 |
| Plant Area |
40,320
ft2
|
| Annual Production | 17,276,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $197,149 | 814,464 |
kWh
|
$0.24 |
| Electricity Demand | $72,622 | 3,503 |
kW-mo/yr
|
$20.73 |
| Electricity Fees | $2,704 | - |
|
- |
| TOTAL YEARLY COSTS | $272,475 | |||
| RECOMMENDED SAVINGS* | $36,236 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $754 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $2,583 | $10,494 |
$2,133
8,804
kWh
|
$450
-
kW-mo/yr
|
|
| 02 | 2.3141: Use battery storage for demand control | $15,108 | $70,650 |
$(-2,445.0)
(-10,100)
kWh
|
$17,553
-
kW-mo/yr
|
|
| 03 | 2.7134: Use photocell controls | $754 | $1,124 |
$754
3,116
kWh
|
- | |
| 04 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $3,553 | $3,535 |
$3,553
14,676
kWh
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,208 | $16,000 |
$8,716
36,000
kWh
|
$1,492
-
kW-mo/yr
|
|
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $928 | $2,934 |
$780
3,222
kWh
|
$148
-
kW-mo/yr
|
|
| 07 | 2.2511: Insulate bare equipment | $1,509 | $4,973 |
$1,262
5,213
kWh
|
$247
-
kW-mo/yr
|
|
| 08 | 2.4221: Install compressor air intakes in coolest locations | $1,593 | $4,339 |
$1,507
6,225
kWh
|
$86
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $36,236 | $114,049 |
$16,260
67,156
kWh
|
$19,976
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $754 | $1,124 |
$754
3,116
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs