Assessment Year 2023
Principal Product Printed Labels, Flexible Packaging Film, Shrink Sleeves
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 25
Plant Area 35,000
ft2
Annual Production 800
units
Production Hrs. Annual 2,167
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,115 662,473
kWh
Electricity Demand $46,069 3,731
kW-mo/yr
Electricity Fees $712 -
TOTAL YEARLY COSTS $131,896
RECOMMENDED SAVINGS* $80,619 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $67,963 $332,640 $41,287
321,300
kWh
$26,676
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $750 $1,100 $438
3,409
kWh
$312
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,372 $4,320 $739
5,746
kWh
$601
-
kW-mo/yr
$32
04 2.4221: Install compressor air intakes in coolest locations $386 $976 $386
3,004
kWh
- -
05 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $9,930 $10,320 $7,115
55,366
kWh
$2,815
-
kW-mo/yr
-
06 2.4224: Upgrade controls on compressors $218 - $218
1,700
kWh
- -
TOTAL RECOMMENDED $80,619 $349,356 $50,183
390,525
kWh
$30,404
-
kW-mo/yr
$32
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs