| Assessment Year | 2021 |
|---|---|
| Principal Product | plastic components |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 230 |
| Plant Area |
72,000
ft2
|
| Annual Production | 1,000,000,000
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $420,757 | 4,422,950 |
kWh
|
$0.095 |
| Electricity Demand | $293,288 | 8,986 |
kW-mo/yr
|
$32.64 |
| Electricity Fees | $30,611 | - |
|
- |
| TOTAL YEARLY COSTS | $744,656 | |||
| RECOMMENDED SAVINGS* | $79,160 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $63,329 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7232: Replace existing hvac unit with high efficiency model | $61,033 | $97,300 |
$45,089
474,122
kWh
|
$15,944
-
kW-mo/yr
|
|
| 02 | 2.4226: Use / purchase optimum sized compressor | $11,002 | $44,000 |
$7,477
78,624
kWh
|
$3,525
-
kW-mo/yr
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $4,829 | $4,700 |
$3,282
34,508
kWh
|
$1,547
-
kW-mo/yr
|
|
| 04 | 2.4239: Eliminate or reduce compressed air usage | $1,978 | - |
$1,978
20,803
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $318 | $600 |
$257
2,699
kWh
|
$61
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $79,160 | $146,600 |
$58,083
610,756
kWh
|
$21,077
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $63,329 | $97,900 |
$47,324
497,624
kWh
|
$16,005
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs