Assessment Year 2016
Principal Product Inter-ocular lenses
NAICS 339112: Surgical and Medical Instrument Manufacturing
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area 80,000
ft2
Annual Production 2,000
pieces
Production Hrs. Annual 5,772
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $179,075 2,326,939
kWh
Electricity Demand $86,936 5,059
kW-mo/yr
Electricity Fees $16,513 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $125,266 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7232: Replace existing hvac unit with high efficiency model $55,828 $139,240 $39,666
515,151
kWh
$16,162
-
kW-mo/yr
- -
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $41,516 $13,343 $22,007
285,805
kWh
$24,739
-
kW-mo/yr
$(-5,230.0)
-
MMBtu
-
03 4.212: Adopt in-house material generation $9,790 $15,235 $(-8.0)
(-94)
kWh
- - $9,798
04 2.7142: Utilize higher efficiency lamps and/or ballasts $9,076 $29,064 $5,109
66,357
kWh
$3,668
-
kW-mo/yr
- $299
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,155 $5,524 $2,820
36,622
kWh
$1,335
-
kW-mo/yr
- -
06 2.7111: Reduce illumination to minimum necessary levels $1,558 $760 $1,057
13,748
kWh
$501
-
kW-mo/yr
- -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,189 $1,000 $782
10,153
kWh
$407
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $883 $2,510 $883
11,462
kWh
- - -
09 2.7261: Install timers and/or thermostats $629 $344 $629
8,166
kWh
- - -
10 2.4231: Reduce the pressure of compressed air to the minimum required $362 $200 $362
4,696
kWh
- - -
11 2.4133: Use most efficient type of electric motors $280 $767 $191
2,475
kWh
$89
-
kW-mo/yr
- -
TOTAL RECOMMENDED $125,266 $207,987 $73,498
954,541
kWh
$46,901
-
kW-mo/yr
$(-5,230.0)
-
MMBtu
$10,097
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs