Assessment Year | 2015 |
---|---|
Principal Product | Control Valves |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3491: Industrial Valves |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
80,175
ft2
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $723,464 | 7,149,360 |
kWh
|
$0.10 |
Electricity Demand | $417,243 | 33,643 |
kW-mo/yr
|
$12.40 |
Electricity Fees | $157,522 | - |
|
- |
Natural Gas | $41,615 | 6,105 |
MMBtu
|
$6.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $210,723 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $91,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $69,718 | $163,200 |
$63,476
627,230
kWh
|
$6,242
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $54,474 | $5,633 |
$42,700
421,933
kWh
|
$11,774
-
kW-mo/yr
|
- | |
03 | 2.7425: Clean or color roof to reduce solar load | $54,235 | $108,000 |
$48,205
476,321
kWh
|
$6,030
-
kW-mo/yr
|
- | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $18,457 | $11,700 |
$18,457
182,354
kWh
|
- | - | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $5,974 | $8,760 | - | - |
$5,974
-
MMBtu
|
|
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,975 | $9,935 |
$3,002
29,144
kWh
|
$1,967
-
kW-mo/yr
|
$(-994.0)
-
MMBtu
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,154 | $2,000 |
$2,520
24,469
kWh
|
$634
-
kW-mo/yr
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $736 | $2,350 |
$489
4,839
kWh
|
$247
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $210,723 | $311,578 |
$178,849
1,766,290
kWh
|
$26,894
-
kW-mo/yr
|
$4,980
-
MMBtu
|
||
TOTAL IMPLEMENTED | $91,329 | $176,900 |
$84,453
834,053
kWh
|
$6,876
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs