Assessment Year 2012
Principal Product Milk Products
NAICS 311511: Fluid Milk Manufacturing
SIC 2026: Fluid Milk
Sales Range $10
M
to 50
M
# of Employees 284
Plant Area 313,000
ft2
Annual Production 50,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,327,437 28,287,289
kWh
Electricity Demand $82,609 54,444
kW-mo/yr
Electricity Fees $1,764 -
Natural Gas $960,697 249,724
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,517 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $11,382 $200 $11,382
242,686
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $13,441 $5,300 $13,016
277,517
kWh
$425
-
kW-mo/yr
-
03 2.4239: Eliminate or reduce compressed air usage $6,465 $2,530 $6,176
131,688
kWh
$289
-
kW-mo/yr
-
04 2.7132: Install timers on light switches in little used areas $706 $252 $676
14,404
kWh
$30
-
kW-mo/yr
-
05 2.7135: Install occupancy sensors $1,808 $1,295 $1,808
38,548
kWh
- -
06 2.2511: Insulate bare equipment $5,541 $4,213 - - $5,541
-
MMBtu
07 2.4221: Install compressor air intakes in coolest locations $3,146 $3,112 $3,066
65,384
kWh
$80
-
kW-mo/yr
-
08 2.2123: Insulate feedwater tank $2,266 $2,574 - - $2,266
-
MMBtu
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,156 $7,124 $4,990
106,402
kWh
$166
-
kW-mo/yr
-
10 2.7134: Use photocell controls $1,606 $2,550 $1,554
33,137
kWh
$52
-
kW-mo/yr
-
TOTAL RECOMMENDED $51,517 $29,150 $42,668
909,766
kWh
$1,042
-
kW-mo/yr
$7,807
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs