Assessment Year | 2012 |
---|---|
Principal Product | PLASTICS (fluoropolymer seals and valves) |
NAICS | 339991: Gasket, Packing, and Sealing Device Manufacturing |
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | less than $500 k |
# of Employees | 237 |
Plant Area |
182,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $367,616 | 5,005,422 |
kWh
|
$0.073 |
Electricity Demand | $265,672 | 12,889 |
kW-mo/yr
|
$20.61 |
Electricity Fees | $7,817 | - |
|
- |
Natural Gas | $64,607 | 99,198 |
MMBtu
|
$0.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,012 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,845 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,992 | $100 |
$1,992
27,144
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,090 | $1,100 |
$8,090
79,729
kWh
|
- | - | |
03 | 2.7132: Install timers on light switches in little used areas | $1,113 | $272 |
$1,113
12,355
kWh
|
- | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $740 | $653 |
$450
6,128
kWh
|
$290
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,560 | $14,000 |
$8,560
158,000
kWh
|
- | - | |
06 | 2.7135: Install occupancy sensors | $1,892 | $3,792 |
$1,892
25,789
kWh
|
- | - | |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $28,752 | $68,368 |
$7,400
100,880
kWh
|
$23,990
-
kW-mo/yr
|
$(-2,638.0)
-
MMBtu
|
|
08 | 2.7425: Clean or color roof to reduce solar load | $7,873 | $20,250 |
$7,873
107,259
kWh
|
- | - | |
TOTAL RECOMMENDED | $59,012 | $108,535 |
$37,370
517,284
kWh
|
$24,280
-
kW-mo/yr
|
$(-2,638.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,845 | $1,025 |
$3,555
45,627
kWh
|
$290
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs