Assessment Year | 2006 |
---|---|
Principal Product | Windows |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | n/a |
# of Employees | 0 |
Plant Area |
175,000
ft2
|
Annual Production | 219,000
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,893 | 1,313,280 |
kWh
|
$0.093 |
Electricity Demand | $27,590 | 2,264 |
kW-mo/yr
|
$12.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,806 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,639 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,290 | $320 |
$12,610
135,885
kWh
|
$4,680
-
kW-mo/yr
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,236 | $5,650 |
$4,236
45,647
kWh
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,237 | $7,600 |
$3,237
34,876
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $2,044 | $146 |
$2,044
22,028
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,694 | $2,217 |
$1,280
13,796
kWh
|
$414
-
kW-mo/yr
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $305 | - |
$305
3,287
kWh
|
- | |
TOTAL RECOMMENDED | $28,806 | $15,933 |
$23,712
255,519
kWh
|
$5,094
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $19,639 | $466 |
$14,959
161,200
kWh
|
$4,680
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs