Assessment Year | 2005 |
---|---|
Principal Product | Cookie |
NAICS | 311821: Cookie and Cracker Manufacturing |
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
80,000
ft2
|
Annual Production | 4,600,000
lb
|
Production Hrs. Annual | 6,468
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,869 | 1,567,182 |
kWh
|
$0.092 |
Electricity Demand | $63,805 | 4,247 |
kW-mo/yr
|
$15.02 |
Natural Gas | $67,841 | 8,173 |
MMBtu
|
$8.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $260,323 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7273: Install desiccant humidity control system | $34,083 | $56,520 | - | - |
$34,083
-
MMBtu
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,494 | $3,900 |
$4,948
53,900
kWh
|
$4,506
-
kW-mo/yr
|
$(-1,960.0)
-
MMBtu
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,208 | - |
$5,066
55,188
kWh
|
$1,142
-
kW-mo/yr
|
- | - | |
04 | 2.4235: Remove or close off unneeded compressed air lines | $1,475 | $450 |
$1,475
16,068
kWh
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,918 | $36,052 |
$10,677
116,308
kWh
|
$3,241
-
kW-mo/yr
|
- | - | |
06 | 2.7134: Use photocell controls | $4,982 | $615 |
$4,982
54,273
kWh
|
- | - | - | |
07 | 2.7135: Install occupancy sensors | $3,212 | $90 |
$3,212
34,992
kWh
|
- | - | - | |
08 | 4.441: Install automatic packing equipment | $171,742 | $50,000 | - | - | - | $171,742 | |
09 | 4.446: Automate finishing process | $17,209 | $30,000 | - | - | - | $17,209 | |
TOTAL RECOMMENDED | $260,323 | $177,627 |
$30,360
330,729
kWh
|
$8,889
-
kW-mo/yr
|
$32,123
-
MMBtu
|
$188,951 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs