Assessment Year | 2004 |
---|---|
Principal Product | Custom plastic injection moldings |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 62 |
Plant Area |
94,000
ft2
|
Annual Production | 15,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $189,113 | 2,425,329 |
kWh
|
$0.078 |
Electricity Demand | $61,724 | 6,159 |
kW-mo/yr
|
$10.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,341 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,343 | $2,475 |
$2,343
30,032
kWh
|
- | - | - | |
02 | 2.2511: Insulate bare equipment | $407 | $151 |
$407
5,219
kWh
|
- | - | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $353 | $700 |
$353
4,532
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,201 | $31,437 |
$10,506
134,688
kWh
|
$2,695
-
kW-mo/yr
|
- | - | |
05 | 2.7134: Use photocell controls | $7,993 | $13,600 |
$7,993
102,480
kWh
|
- | - | - | |
06 | 3.5217: Reuse / recycle/ sell paper products | $15,930 | $17,000 | - | - | - |
$15,930
-
lb
|
|
07 | 2.3212: Optimize plant power factor | $3,058 | - | - | - | $3,058 | - | |
TOTAL RECOMMENDED | $43,285 | $65,363 |
$21,602
276,951
kWh
|
$2,695
-
kW-mo/yr
|
$3,058 |
$15,930
-
lb
|
||
TOTAL IMPLEMENTED | $19,341 | $17,700 |
$353
4,532
kWh
|
- | $3,058 |
$15,930
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs