Assessment Year | 2003 |
---|---|
Principal Product | Aerospace fasteners |
NAICS | 332722: Bolt, Nut, Screw, Rivet, and Washer Manufacturing |
SIC | 3452: Bolts, Nuts, Screws, Rivets, and Washers |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
77,000
ft2
|
Annual Production | 200,000
lb
|
Production Hrs. Annual | 5,087
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $243,649 | 2,119,924 |
kWh
|
$0.11 |
Electricity Demand | $88,106 | 6,508 |
kW-mo/yr
|
$13.54 |
Electricity Fees | $9,029 | - |
|
- |
Natural Gas | $12,086 | 1,950 |
MMBtu
|
$6.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $126,994 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $887 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $20,782 | $1,425 |
$17,182
146,231
kWh
|
$3,600
-
kW-mo/yr
|
- | - | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,189 | $6,000 |
$1,309
11,138
kWh
|
$2,194
-
kW-mo/yr
|
$(-314.0)
-
MMBtu
|
- | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,836 | $4,000 |
$1,454
12,375
kWh
|
$731
-
kW-mo/yr
|
$(-349.0)
-
MMBtu
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $887 | $80 |
$724
6,159
kWh
|
$163
-
kW-mo/yr
|
- | - | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,500 | $10,000 | - | - | - |
$3,500
-
lb
|
- | |
06 | 4.446: Automate finishing process | $96,800 | $200,000 | - | - | - | - | $96,800 | |
TOTAL RECOMMENDED | $126,994 | $221,505 |
$20,669
175,903
kWh
|
$6,688
-
kW-mo/yr
|
$(-663.0)
-
MMBtu
|
$3,500
-
lb
|
$96,800 | ||
TOTAL IMPLEMENTED | $887 | $80 |
$724
6,159
kWh
|
$163
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs