Assessment Year | 1999 |
---|---|
Principal Product | paint and coatings |
NAICS |
n/a
|
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
91,250
ft2
|
Annual Production | 485
Tgal
|
Production Hrs. Annual | 2,677
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,730 | 1,049,824 |
kWh
|
$0.077 |
Electricity Demand | $41,676 | 5,251 |
kW-mo/yr
|
$7.94 |
Natural Gas | $493 | 69 |
MMBtu
|
$7.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $220,375 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $48,333 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7144: Install spectral reflectors / delamp | $3,382 | $7,776 |
$2,436
31,653
kWh
|
$946
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,361 | $1,782 |
$980
12,896
kWh
|
$381
-
kW-mo/yr
|
- | - | - | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,356 | - |
$2,294
29,894
kWh
|
$1,062
-
kW-mo/yr
|
- | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,218 | $23,830 |
$5,530
74,443
kWh
|
$12,688
-
kW-mo/yr
|
- | - | - | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $5,852 | - |
$5,852
76,202
kWh
|
- | - | - | - | |
06 | 2.2612: Use cooling tower water instead of refrigeration | $3,794 | $14,000 |
$2,595
33,705
kWh
|
$1,199
-
kW-mo/yr
|
- | - | - | |
07 | 4.311: Schedule deliveries according to demand | $7,690 | - | - | - | - | - | $7,690 | |
08 | 3.7212: Improved material handling (mixing and transfer) | $594 | - | - | - | - |
$594
-
lb
|
- | |
09 | 3.8143: Recycle cleaning solvent and reuse | $34,580 | $20,000 | - | - |
$34,580
-
gal
|
- | - | |
10 | 4.111: Add equipment/ operators to reduce production bottleneck | $107,143 | $115,000 | - | - | - | - | $107,143 | |
11 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $21,793 | - | - |
$21,793
-
kW-mo/yr
|
- | - | - | |
12 | 4.211: Consider use / purchase of bulk materials where possible | $4,290 | $8,840 | - | - | - | - | $4,290 | |
13 | 4.211: Consider use / purchase of bulk materials where possible | $3,960 | - | - | - | - | - | $3,960 | |
14 | 2.3132: Recharge batteries on during off-peak demand periods | $4,362 | $1,078 | - |
$4,362
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $220,375 | $192,306 |
$19,687
258,793
kWh
|
$42,431
-
kW-mo/yr
|
$34,580
-
gal
|
$594
-
lb
|
$123,083 | ||
TOTAL IMPLEMENTED | $48,333 | $24,908 |
$5,530
74,443
kWh
|
$38,843
-
kW-mo/yr
|
- | - | $3,960 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs