| Assessment Year | 1998 |
|---|---|
| Principal Product | Solar control window films |
| NAICS |
n/a
|
| SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
71,000
ft2
|
| Annual Production | 6,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $591,972 | 6,276,085 |
kWh
|
$0.094 |
| Electricity Demand | $263,282 | 15,556 |
kW-mo/yr
|
$16.92 |
| Natural Gas | $72,639 | 50,568 |
MMBtu
|
$1.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,754 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $39,454 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,033 | $1,033 |
$640
13,482
kWh
|
$393
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,892 | $6,734 |
$872
18,171
kWh
|
$1,020
-
kW-mo/yr
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $1,393 | $300 |
$1,393
29,015
kWh
|
- | - | |
| 04 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $13,056 | - | - | - | $13,056 | |
| 05 | 3.6192: Use a less expensive method of waste removal | $22,080 | - | - | - | $22,080 | |
| 06 | 4.423: Move product using mechanical means | $1,575 | $2,000 | - | - | $1,575 | |
| 07 | 4.431: Train operators for maximum operating efficiency | $4,725 | - | - | - | $4,725 | |
| TOTAL RECOMMENDED | $45,754 | $10,067 |
$2,905
60,668
kWh
|
$1,413
-
kW-mo/yr
|
$41,436 | ||
| TOTAL IMPLEMENTED | $39,454 | $8,067 |
$2,905
60,668
kWh
|
$1,413
-
kW-mo/yr
|
$35,136 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs