Assessment Year | 1998 |
---|---|
Principal Product | Commercial printing for entertainment industry |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
20,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 5,336
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $138,749 | 2,423,505 |
kWh
|
$0.057 |
Electricity Demand | $9,076 | 6,840 |
kW-mo/yr
|
$1.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $682,248 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,191 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $6,365 | $3,993 |
$5,950
104,338
kWh
|
$415
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,284 | - |
$5,948
104,338
kWh
|
$336
-
kW-mo/yr
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $807 | $405 |
$807
14,068
kWh
|
- | - | - | |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $7,100 | $8,500 | - | - | $7,100 | - | |
05 | 3.2171: Use an automatic plate processor | $656,267 | $405,000 | - | - | - | $656,267 | |
06 | 4.111: Add equipment/ operators to reduce production bottleneck | $5,425 | $7,000 | - | - | $5,425 | - | |
TOTAL RECOMMENDED | $682,248 | $424,898 |
$12,705
222,744
kWh
|
$751
-
kW-mo/yr
|
$12,525 | $656,267 | ||
TOTAL IMPLEMENTED | $14,191 | $8,905 |
$6,755
118,406
kWh
|
$336
-
kW-mo/yr
|
$7,100 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs