Assessment Year | 1997 |
---|---|
Principal Product | Transformers, inductors and electric components for major in |
NAICS |
n/a
|
SIC | 3677: Electronic Coils, Transformers, and Other Inductors |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
27,000
ft2
|
Annual Production | 3,200
pieces
|
Production Hrs. Annual | 2,167
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,407 | 1,009,672 |
kWh
|
$0.082 |
Electricity Demand | $28,948 | 3,566 |
kW-mo/yr
|
$8.12 |
Natural Gas | $1,991 | 263 |
MMBtu
|
$7.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,746 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,349 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4226: Use / purchase optimum sized compressor | $721 | $1,200 |
$558
6,741
kWh
|
$163
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,934 | $17,722 |
$6,327
77,081
kWh
|
$2,607
-
kW-mo/yr
|
- | - | |
03 | 2.7144: Install spectral reflectors / delamp | $15,429 | $16,085 |
$10,936
133,353
kWh
|
$4,493
-
kW-mo/yr
|
- | - | |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,120 | $2,000 | - | - | - | $3,120 | |
05 | 3.8224: Convert to less toxic hydrocarbon cleaners | $4,145 | - | - | - |
$4,145
-
gal
|
- | |
06 | 3.1175: Use a different or recycled raw material | $2,397 | $320 | - | - | - | $2,397 | |
TOTAL RECOMMENDED | $34,746 | $37,327 |
$17,821
217,175
kWh
|
$7,263
-
kW-mo/yr
|
$4,145
-
gal
|
$5,517 | ||
TOTAL IMPLEMENTED | $32,349 | $37,007 |
$17,821
217,175
kWh
|
$7,263
-
kW-mo/yr
|
$4,145
-
gal
|
$3,120 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs