| Assessment Year | 1995 |
|---|---|
| Principal Product | Multi-Layered Printed Circuit Boards |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
44,000
ft2
|
| Annual Production | 600,000
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $362,256 | 4,356,096 |
kWh
|
$0.083 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,117 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,717 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4226: Use / purchase optimum sized compressor | $8,690 | $8,500 |
$8,690
98,476
kWh
|
- | - | - | |
| 02 | 2.2694: Use highest temperature for chilling or cold storage | $3,798 | $4,900 |
$3,798
61,254
kWh
|
- | - | - | |
| 03 | 2.2511: Insulate bare equipment | $948 | $238 |
$948
13,775
kWh
|
- | - | - | |
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $765 | $1,600 |
$765
8,499
kWh
|
- | - | - | |
| 05 | 2.2223: Enhance sensitivity of temperature control and cutoff | $608 | - |
$608
9,672
kWh
|
- | - | - | |
| 06 | 2.7134: Use photocell controls | $1,654 | $305 |
$1,654
15,240
kWh
|
- | - | - | |
| 07 | 3.6112: Use filter and drying oven to reduce sludge volume | $2,000 | $2,000 | - | - |
$2,000
-
gal
|
- | |
| 08 | 3.4113: Treat and reuse rinse waters | $1,893 | $300 | - |
$1,893
-
Tgal
|
- | - | |
| 09 | 3.1244: Reduce solution drag-out to prevent solution loss | $2,400 | $500 | - | - |
$2,400
-
gal
|
- | |
| 10 | 3.5241: Sell used plates to an aluminum recycler | $2,361 | - | - | - | - |
$2,361
-
lb
|
|
| TOTAL RECOMMENDED | $25,117 | $18,343 |
$16,463
206,916
kWh
|
$1,893
-
Tgal
|
$4,400
-
gal
|
$2,361
-
lb
|
||
| TOTAL IMPLEMENTED | $11,717 | $10,405 |
$11,717
131,887
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs