ITAC Assessment: SD0071
ITAC logo
ITAC Assessment: SD0071
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product PVC Pipes
NAICS
n/a
SIC 3084: Plastics Pipe
Sales Range $10
M
to 50
M
# of Employees 68
Plant Area 44,000
ft2
Annual Production 52,000,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $760,142 9,344,373
kWh
Natural Gas $14,308 2,245
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $75,573 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $53,662

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $27,894 $27,500 $27,894
342,907
kWh
02 2.2511: Insulate bare equipment $473 $136 $473
5,862
kWh
03 2.2424: Use heat in flue gases to preheat products or materials $15,214 $24,880 $15,214
186,987
kWh
04 2.2614: Use cooling tower or economizer to replace chiller cooling $16,815 $8,515 $16,815
206,624
kWh
05 2.3131: Reschedule plant operations or reduce load to avoid peaks $8,613 - $8,613
33,705
kWh
06 2.7261: Install timers and/or thermostats $587 $300 $587
7,327
kWh
07 2.7142: Utilize higher efficiency lamps and/or ballasts $881 $3,241 $881
9,086
kWh
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,220 $1,800 $1,220
13,189
kWh
09 2.7132: Install timers on light switches in little used areas $2,892 $240 $2,892
32,532
kWh
10 2.7135: Install occupancy sensors $723 $800 $723
7,913
kWh
11 2.7142: Utilize higher efficiency lamps and/or ballasts $261 $228 $261
2,931
kWh
TOTAL RECOMMENDED $75,573 $67,640 $75,573
849,063
kWh
TOTAL IMPLEMENTED $53,662 $56,057 $53,662
585,874
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs