ITAC Assessment: SD0068
ITAC logo
ITAC Assessment: SD0068
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product NYLON CARPETS
NAICS
n/a
SIC 2273: Carpets and Rugs
Sales Range $5
M
to 10
M
# of Employees 66
Plant Area
n/a
Annual Production 7,920
thousand feet
Production Hrs. Annual 3,788
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $251,604 2,674,678
kWh
Natural Gas $518,051 129,796
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $84,347 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,617

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $731 $750 $731
7,913
kWh
- -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,666 $17,938 $6,666
70,926
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,035 $140 $4,035
42,790
kWh
- -
04 2.2136: Install / repair insulation on steam lines $149 $264 - $149
-
MMBtu
-
05 2.2135: Repair and eliminate steam leaks $6,065 $800 - $6,065
-
MMBtu
-
06 2.2449: Recover heat from exhausted steam, hot air or hot water $58,730 $33,300 - $58,730
-
MMBtu
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,576 $1,230 $2,640
28,136
kWh
- $(-64.0)
08 2.7144: Install spectral reflectors / delamp $1,560 $1,470 $1,442
15,240
kWh
- $118
09 2.6232: Install set-back timers $1,458 $2,000 $1,352
14,361
kWh
- $106
10 2.7142: Utilize higher efficiency lamps and/or ballasts $1,598 $852 $1,484
15,826
kWh
- $114
11 2.7142: Utilize higher efficiency lamps and/or ballasts $779 $350 $370
3,810
kWh
- $409
TOTAL RECOMMENDED $84,347 $59,094 $18,720
199,002
kWh
$64,944
-
MMBtu
$683
TOTAL IMPLEMENTED $25,617 $25,794 $18,720
199,002
kWh
$6,214
-
MMBtu
$683
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs