Assessment Year | 1993 |
---|---|
Principal Product | SASH AND DOOR MATERIALS |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 16,000
thousand feet
|
Production Hrs. Annual | 3,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,535 | 1,142,145 |
kWh
|
$0.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,412 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,738 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,002 | $1,890 |
$1,002
9,965
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,549 | $3,320 |
$1,549
15,533
kWh
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $223 | $20 |
$223
2,345
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $544 | $80 |
$544
5,569
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $102 | - |
$129
1,172
kWh
|
$(-27.0) | |
06 | 2.6232: Install set-back timers | $771 | $1,080 |
$679
6,741
kWh
|
$92 | |
07 | 2.7144: Install spectral reflectors / delamp | $1,314 | $2,080 |
$1,158
11,430
kWh
|
$156 | |
08 | 2.7134: Use photocell controls | $907 | $1,715 |
$832
8,206
kWh
|
$75 | |
TOTAL RECOMMENDED | $6,412 | $10,185 |
$6,116
60,961
kWh
|
$296 | ||
TOTAL IMPLEMENTED | $4,738 | $8,370 |
$4,517
44,841
kWh
|
$221 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs