| Assessment Year | 2017 |
|---|---|
| Principal Product | Machined products for WW and wter industry |
| NAICS | 333515: Cutting Tool and Machine Tool Accessory Manufacturing |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 17 |
| Plant Area |
110,625
ft2
|
| Annual Production | 52,000
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $162,440 | 1,466,290 |
kWh
|
$0.11 |
| Electricity Demand | $25,739 | 4,731 |
kW-mo/yr
|
$5.44 |
| Electricity Fees | $20,960 | - |
|
- |
| LPG | $34,545 | 1,924 |
MMBtu
|
$17.95 |
| TOTAL YEARLY COSTS | $243,684 | |||
| RECOMMENDED SAVINGS* | $28,662 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,281 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $18,221 | $78,750 |
$29,174
262,832
kWh
|
$(-10,953.0)
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $7,638 | $1,583 |
$7,638
68,807
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,366 | $600 |
$2,366
21,313
kWh
|
- | |
| 04 | 2.6218: Turn off equipment when not in use | $277 | $100 |
$277
2,499
kWh
|
- | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $160 | $100 |
$160
1,447
kWh
|
- | |
| TOTAL RECOMMENDED | $28,662 | $81,133 |
$39,615
356,898
kWh
|
$(-10,953.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,281 | $2,283 |
$10,281
92,619
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs