Assessment Year 1992
Principal Product FILAMENT WOUND FIBERGLAS
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 91
Plant Area
n/a
Annual Production 12,379
pieces
Production Hrs. Annual 4,535
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $99,417 990,035
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,182 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,182

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $490 $535 $490
4,982
kWh
-
02 2.6232: Install set-back timers $846 $966 $756
7,620
kWh
$90
03 2.7142: Utilize higher efficiency lamps and/or ballasts $356 $966 $451
4,396
kWh
$(-95.0)
04 2.7123: Keep lamps and reflectors clean $745 $3,200 $568
4,396
kWh
$177
05 2.7144: Install spectral reflectors / delamp $1,745 - $1,745
15,533
kWh
-
TOTAL RECOMMENDED $4,182 $5,667 $4,010
36,927
kWh
$172
TOTAL IMPLEMENTED $4,182 $5,667 $4,010
36,927
kWh
$172