ITAC Assessment: SD0025
ITAC logo
ITAC Assessment: SD0025
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product POWER SYSTEMS/GENERATORS
NAICS
n/a
SIC 3621: Motors and Generators
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area
n/a
Annual Production 2,000
pieces
Production Hrs. Annual 5,304
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $96,111 1,071,219
kWh
Natural Gas $14,316 2,232
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,541 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,799

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $130 $900 $130
1,465
kWh
- -
02 2.6218: Turn off equipment when not in use $710 $120 $710
7,913
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $16,866 $2,000 $16,866
187,866
kWh
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $582 $45 $582
6,448
kWh
- -
05 2.4322: Use or replace with energy efficient substitutes $4,093 $4,450 - $4,093
-
MMBtu
-
06 2.2511: Insulate bare equipment $338 $77 - $338
-
MMBtu
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $785 $925 $447
4,982
kWh
- $338
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,781 $1,200 $1,781
17,292
kWh
- -
09 2.6232: Install set-back timers $2,785 $3,240 $2,785
27,257
kWh
- -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $1,471 $1,980 $1,471
23,447
kWh
- -
TOTAL RECOMMENDED $29,541 $14,937 $24,772
276,670
kWh
$4,431
-
MMBtu
$338
TOTAL IMPLEMENTED $21,799 $7,470 $17,706
197,244
kWh
$4,093
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs