| Assessment Year | 1991 |
|---|---|
| Principal Product | PORTABLE HOT TUBS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 370 |
| Plant Area |
n/a
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $241,512 | 2,665,885 |
kWh
|
$0.091 |
| Natural Gas | $8,875 | 1,373 |
MMBtu
|
$6.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,290 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $4,725 | $3,100 |
$4,725
52,169
kWh
|
|
| 02 | 2.2531: Re-size charging openings or add movable cover or door | $11,147 | $300 |
$11,147
123,095
kWh
|
|
| 03 | 2.6232: Install set-back timers | $1,086 | $5,550 |
$1,086
12,016
kWh
|
|
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $580 | $600 |
$580
6,448
kWh
|
|
| 05 | 2.7123: Keep lamps and reflectors clean | $752 | $3,780 |
$752
8,206
kWh
|
|
| TOTAL RECOMMENDED | $18,290 | $13,330 |
$18,290
201,934
kWh
|
||
| TOTAL IMPLEMENTED | $18,290 | $13,330 |
$18,290
201,934
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs