| Assessment Year | 1992 |
|---|---|
| Principal Product | COMMERCIAL INKS |
| NAICS |
n/a
|
| SIC | 2893: Printing Ink |
| Sales Range | $10 M to 50M |
| # of Employees | 161 |
| Plant Area |
n/a
|
| Annual Production | 560
Tgal
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $90,688 | 762,603 |
kWh
|
$0.12 |
| Natural Gas | $27,524 | 4,705 |
MMBtu
|
$5.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,914 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4312: Improve lubrication practices | $1,620 | $800 |
$1,620
13,775
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,261 | $1,500 |
$2,480
20,809
kWh
|
- | $(-219.0) | |
| 03 | 2.4133: Use most efficient type of electric motors | $653 | $632 |
$653
5,569
kWh
|
- | - | |
| 04 | 2.3191: Use demand controller or load shedder | $2,293 | $2,500 |
$2,293
-
kWh
|
- | - | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $2,172 | - | - |
$2,172
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $8,999 | $5,432 |
$7,046
40,153
kWh
|
$2,172
-
MMBtu
|
$(-219.0) | ||
| TOTAL IMPLEMENTED | $2,914 | $2,132 |
$3,133
26,378
kWh
|
- | $(-219.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs