Assessment Year | 2005 |
---|---|
Principal Product | Plastic Injection Molded Containers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
64,000
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,132 | 2,715,520 |
kWh
|
$0.025 |
Electricity Demand | $52,004 | 9,234 |
kW-mo/yr
|
$5.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,865 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $7,102 | $34,362 |
$3,856
154,227
kWh
|
$3,246
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,418 | $744 |
$6,418
145,857
kWh
|
- | |
03 | 2.2615: Clean condenser tubes | $2,414 | $12,044 |
$2,414
54,857
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,698 | $8,619 |
$1,200
47,980
kWh
|
$499
-
kW-mo/yr
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $988 | - |
$988
22,445
kWh
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,405 | - |
$1,405
31,928
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $1,246 | $6,221 |
$783
31,309
kWh
|
$463
-
kW-mo/yr
|
|
08 | 2.7135: Install occupancy sensors | $585 | $332 |
$585
13,295
kWh
|
- | |
09 | 3.5212: Regrind, reuse, or sell scrap plastic parts | - | - | - | - | |
TOTAL RECOMMENDED | $21,855 | $62,322 |
$17,647
501,898
kWh
|
$4,208
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $19,865 | $61,990 |
$15,657
456,675
kWh
|
$4,208
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs