Assessment Year 2005
Principal Product Plastic Injection Molded Containers
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 70
Plant Area 64,000
ft2
Annual Production 2,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $68,132 2,715,520
kWh
Electricity Demand $52,004 9,234
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,855 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,865

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7121: Utilize daylight whenever possible in lieu of artificial light $7,102 $34,362 $3,856
154,227
kWh
$3,246
-
kW-mo/yr
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,418 $744 $6,418
145,857
kWh
-
03 2.2615: Clean condenser tubes $2,414 $12,044 $2,414
54,857
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,698 $8,619 $1,200
47,980
kWh
$499
-
kW-mo/yr
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $988 - $988
22,445
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $1,405 - $1,405
31,928
kWh
-
07 2.4133: Use most efficient type of electric motors $1,246 $6,221 $783
31,309
kWh
$463
-
kW-mo/yr
08 2.7135: Install occupancy sensors $585 $332 $585
13,295
kWh
-
09 3.5212: Regrind, reuse, or sell scrap plastic parts - - - -
TOTAL RECOMMENDED $21,855 $62,322 $17,647
501,898
kWh
$4,208
-
kW-mo/yr
TOTAL IMPLEMENTED $19,865 $61,990 $15,657
456,675
kWh
$4,208
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs