| Assessment Year | 1992 |
|---|---|
| Principal Product | PLASTIC FILMS |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $1 M to 5M |
| # of Employees | 18 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,122 | 1,442,556 |
kWh
|
$0.081 |
| Natural Gas | $3,660 | 575 |
MMBtu
|
$6.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,735 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,251 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,857 | - |
$2,857
35,170
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $591 | $40 |
$671
8,206
kWh
|
$(-80.0) | |
| 03 | 2.4312: Improve lubrication practices | $1,884 | $800 |
$1,884
23,154
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $803 | $36,020 |
$803
9,965
kWh
|
- | |
| 05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,600 | $2,500 |
$5,600
-
kWh
|
- | |
| TOTAL RECOMMENDED | $11,735 | $39,360 |
$11,815
76,495
kWh
|
$(-80.0) | ||
| TOTAL IMPLEMENTED | $4,251 | $36,060 |
$4,331
53,341
kWh
|
$(-80.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs