Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC FILMS |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $1 M to 5M |
# of Employees | 18 |
Plant Area |
n/a
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $117,122 | 1,442,556 |
kWh
|
$0.081 |
Natural Gas | $3,660 | 575 |
MMBtu
|
$6.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,735 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,251 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,857 | - |
$2,857
35,170
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $591 | $40 |
$671
8,206
kWh
|
$(-80.0) | |
03 | 2.4312: Improve lubrication practices | $1,884 | $800 |
$1,884
23,154
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $803 | $36,020 |
$803
9,965
kWh
|
- | |
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,600 | $2,500 |
$5,600
-
kWh
|
- | |
TOTAL RECOMMENDED | $11,735 | $39,360 |
$11,815
76,495
kWh
|
$(-80.0) | ||
TOTAL IMPLEMENTED | $4,251 | $36,060 |
$4,331
53,341
kWh
|
$(-80.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs