Assessment Year | 1991 |
---|---|
Principal Product | COATING OF ANODES |
NAICS |
n/a
|
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 3,367
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $267,113 | 3,322,978 |
kWh
|
$0.080 |
Natural Gas | $1,816 | 245 |
MMBtu
|
$7.41 |
Fuel Oil #4 | $43,478 | 8,877 |
MMBtu
|
$4.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,851 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,851 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $376 | $231 |
$376
4,689
kWh
|
|
02 | 2.6232: Install set-back timers | $4,619 | $1,912 |
$4,619
57,737
kWh
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $1,548 | - |
$1,548
19,343
kWh
|
|
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $18,308 | - |
$18,308
-
kWh
|
|
TOTAL RECOMMENDED | $24,851 | $2,143 |
$24,851
81,769
kWh
|
||
TOTAL IMPLEMENTED | $24,851 | $2,143 |
$24,851
81,769
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs