Assessment Year | 1990 |
---|---|
Principal Product | PUMPS |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 4,000
pieces
|
Production Hrs. Annual | 4,836
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,222 | 842,614 |
kWh
|
$0.10 |
Natural Gas | $950 | 105 |
MMBtu
|
$9.05 |
Fuel Oil #2 | $22,790 | 5,166 |
MMBtu
|
$4.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,332 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,262 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $664 | $3,750 |
$664
6,448
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,830 | - | - |
$1,830
-
MMBtu
|
|
03 | 2.4312: Improve lubrication practices | $857 | $800 |
$857
8,206
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $1,213 | $12,352 | - |
$1,213
-
MMBtu
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $12,768 | $133,665 |
$5,106
49,531
kWh
|
$7,662
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,332 | $150,567 |
$6,627
64,185
kWh
|
$10,705
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,262 | $137,415 |
$5,770
55,979
kWh
|
$9,492
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs