Assessment Year | 1990 |
---|---|
Principal Product | COSTUME STAMPING |
NAICS |
n/a
|
SIC | 3495: Wire Springs |
Sales Range | $10 M to 50M |
# of Employees | 133 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $326,853 | 2,935,815 |
kWh
|
$0.11 |
Natural Gas | $6,569 | 1,328 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,962 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $976 | - |
$976
8,792
kWh
|
|
02 | 2.2514: Cover open tanks | $16,298 | $1,468 |
$16,298
146,835
kWh
|
|
03 | 2.7492: Use proper thickness of insulation on building envelope | $34,441 | $74,800 |
$34,441
310,375
kWh
|
|
04 | 2.7494: Install storm windows and doors | $545 | $750 |
$545
4,982
kWh
|
|
TOTAL RECOMMENDED | $52,260 | $77,018 |
$52,260
470,984
kWh
|
||
TOTAL IMPLEMENTED | $35,962 | $75,550 |
$35,962
324,149
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs