Assessment Year | 1990 |
---|---|
Principal Product | ROOF TRUSSES |
NAICS |
n/a
|
SIC | 2439: Structural Wood Members, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 103
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,143 | 1,024,912 |
kWh
|
$0.081 |
Natural Gas | $12,365 | 2,346 |
MMBtu
|
$5.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,936 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,254 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,951 | $80 |
$1,951
24,912
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $295 | - |
$295
7,034
kWh
|
|
03 | 3.4151: Minimize water usage | $387 | $34 |
$387
4,689
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,303 | - |
$3,303
40,739
kWh
|
|
TOTAL RECOMMENDED | $5,936 | $114 |
$5,936
77,374
kWh
|
||
TOTAL IMPLEMENTED | $5,254 | $80 |
$5,254
65,651
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs