Assessment Year | 1990 |
---|---|
Principal Product | METAL FASTERNERS |
NAICS |
n/a
|
SIC | 3429: Hardware, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 195 |
Plant Area |
n/a
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $287,119 | 3,825,616 |
kWh
|
$0.075 |
Natural Gas | $294,371 | 57,742 |
MMBtu
|
$5.10 |
Fuel Oil #2 | $27,721 | 6,021 |
MMBtu
|
$4.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $96,042 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,062 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,358 | $325 |
$2,358
31,360
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,191 | $2,368 |
$2,191
29,308
kWh
|
- | |
03 | 2.8113: Purchase gas directly from a contract gas supplier | $51,967 | $50,000 | - |
$51,967
-
MMBtu
|
|
04 | 2.7229: Air condition only space necessary | $3,851 | $6,100 | - |
$3,851
-
MMBtu
|
|
05 | 2.2414: Use waste heat from hot flue gases to preheat | $14,994 | $17,800 | - |
$14,994
-
MMBtu
|
|
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $17,662 | - | - |
$17,662
-
MMBtu
|
|
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,019 | - |
$3,019
40,152
kWh
|
- | |
TOTAL RECOMMENDED | $96,042 | $76,593 |
$7,568
100,820
kWh
|
$88,474
-
MMBtu
|
||
TOTAL IMPLEMENTED | $26,062 | $8,793 |
$4,549
60,668
kWh
|
$21,513
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs