Assessment Year | 2011 |
---|---|
Principal Product | Manufacturing Converting Machinery |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
123,246
ft2
|
Annual Production | 20
units
|
Production Hrs. Annual | 5,460
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,794 | 2,257,844 |
kWh
|
$0.077 |
Electricity Demand | $104,241 | 6,922 |
kW-mo/yr
|
$15.06 |
Electricity Fees | $7,040 | - |
|
- |
Natural Gas | $146,994 | 16,585 |
MMBtu
|
$8.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,125 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,986 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $786 | $196 |
$786
10,920
kWh
|
- | - | - | |
02 | 2.6211: Conserve energy by efficient use of vending machines | $344 | $645 |
$344
4,780
kWh
|
- | - | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $12,040 | $34,682 |
$(-924.0)
(-12,830)
kWh
|
- | - |
$12,964
-
MMBtu
|
|
04 | 2.3212: Optimize plant power factor | $4,313 | $16,531 | - | - | $4,313 | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,642 | $60,207 |
$6,739
93,603
kWh
|
$4,903
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $29,125 | $112,261 |
$6,945
96,473
kWh
|
$4,903
-
kW-mo/yr
|
$4,313 |
$12,964
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,986 | $60,852 |
$7,083
98,383
kWh
|
$4,903
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs