Assessment Year | 1989 |
---|---|
Principal Product | INSTRUMENT COMPONENTS |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,065 | 441,090 |
kWh
|
$0.091 |
LPG | $11,432 | 1,649 |
MMBtu
|
$6.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,693 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,588 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $2,588 | $2,880 |
$(-301.0)
(-3,517)
kWh
|
$2,889
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $785 | $203 |
$785
8,499
kWh
|
- | |
03 | 2.7444: Close holes and openings in building such as broken windows | $1,320 | - |
$1,320
14,654
kWh
|
- | |
TOTAL RECOMMENDED | $4,693 | $3,083 |
$1,804
19,636
kWh
|
$2,889
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,588 | $2,880 |
$(-301.0)
(-3,517)
kWh
|
$2,889
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs