Assessment Year 1989
Principal Product TEFLON & PVC COATED WIRE
NAICS
n/a
SIC 3357: Drawing and Insulating of Nonferrous Wire
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area
n/a
Annual Production 24,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $256,322 3,558,031
kWh
Natural Gas $38,910 8,032
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,978 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,476

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $3,402 $441 $3,402
47,186
kWh
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,029 - $1,029
14,361
kWh
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,097 $9,000 $1,097
15,240
kWh
04 2.4312: Improve lubrication practices $557 $400 $557
7,620
kWh
05 2.4221: Install compressor air intakes in coolest locations $1,670 $594 $1,670
23,154
kWh
06 2.4231: Reduce the pressure of compressed air to the minimum required $1,506 - $1,506
20,809
kWh
07 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $1,869 - $1,869
26,084
kWh
08 2.6212: Turn off equipment during breaks, reduce operating time $16,848 - $16,848
233,880
kWh
TOTAL RECOMMENDED $27,978 $10,435 $27,978
388,334
kWh
TOTAL IMPLEMENTED $9,476 $1,035 $9,476
131,594
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs