| Assessment Year | 1988 |
|---|---|
| Principal Product | RIGID PVC PRODUCTS |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 123 |
| Plant Area |
n/a
|
| Annual Production | 22,500,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $597,895 | 9,919,109 |
kWh
|
$0.060 |
| Natural Gas | $123,166 | 19,975 |
MMBtu
|
$6.17 |
| Fuel Oil #2 | $70,637 | 19,390 |
MMBtu
|
$3.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,842 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,841 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,016 | $400 |
$3,016
50,410
kWh
|
- | |
| 02 | 2.4312: Improve lubrication practices | $3,797 | $1,600 |
$3,797
63,306
kWh
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $2,084 | $2,520 |
$(-200.0)
(-3,224)
kWh
|
$2,284
-
MMBtu
|
|
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,825 | $2,500 | - |
$2,825
-
MMBtu
|
|
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $35,120 | $25,000 | - |
$35,120
-
MMBtu
|
|
| TOTAL RECOMMENDED | $46,842 | $32,020 |
$6,613
110,492
kWh
|
$40,229
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,841 | $2,900 |
$3,016
50,410
kWh
|
$2,825
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs