| Assessment Year | 1987 |
|---|---|
| Principal Product | THERMOPLASTIC EXTRUSION |
| NAICS |
n/a
|
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $5 M to 10M |
| # of Employees | 105 |
| Plant Area |
n/a
|
| Annual Production | 53,000,000
pieces
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $136,003 | 1,987,104 |
kWh
|
$0.068 |
| Natural Gas | $21,723 | 3,879 |
MMBtu
|
$5.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,395 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,105 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,628 | $376 |
$2,628
38,687
kWh
|
|
| 02 | 2.2514: Cover open tanks | $3,290 | $200 |
$3,290
48,066
kWh
|
|
| 03 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $822 | $31 |
$822
12,016
kWh
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,104 | - |
$4,104
60,375
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,551 | - |
$3,551
51,876
kWh
|
|
| TOTAL RECOMMENDED | $14,395 | $607 |
$14,395
211,020
kWh
|
||
| TOTAL IMPLEMENTED | $11,105 | $407 |
$11,105
162,954
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs