Assessment Year | 2023 |
---|---|
Principal Product | Sheet Glass |
NAICS | 327211: Flat Glass Manufacturing |
SIC | 3211: Flat Glass |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
75,000
ft2
|
Annual Production | 4,400,000
lb
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $127,360 | 1,800,354 |
kWh
|
$0.071 |
Electricity Demand | $65,242 | 8,593 |
kW-mo/yr
|
$7.59 |
Electricity Fees | $17,186 | - |
|
- |
Natural Gas | $13,248 | 1,022 |
MMBtu
|
$12.96 |
TOTAL YEARLY COSTS | $223,036 | |||
RECOMMENDED SAVINGS* | $62,215 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $27,206 | $88,913 |
$4,651
46,629
kWh
|
- |
$22,555
-
MMBtu
|
|
02 | 2.1122: Re-size charging openings or add a movable door on equipment | $22,803 | $17,436 | - | - |
$22,803
-
MMBtu
|
|
03 | 2.4224: Upgrade controls on compressors | $10,951 | $10,710 |
$10,951
109,791
kWh
|
- | - | |
04 | 2.4323: Use optimum size and capacity equipment | $1,255 | $1,480 |
$992
9,948
kWh
|
$263
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $62,215 | $118,539 |
$16,594
166,368
kWh
|
$263
-
kW-mo/yr
|
$45,358
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs