ITAC Assessment: OR0762
ITAC logo
ITAC Assessment: OR0762
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Dimentional Lumber
NAICS 321113: Sawmills
SIC 2421: Sawmills and Planing Mills, General
Sales Range $10
M
to 50
M
# of Employees 80
Plant Area 3,735,000
ft2
Annual Production 60,000
thousand feet
Production Hrs. Annual 2,600
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $469,460 10,743,800
kWh
Electricity Demand $404,518 37,422
kW-mo/yr
Electricity Fees $110,213 -
TOTAL YEARLY COSTS $984,191
RECOMMENDED SAVINGS* $248,167 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $94,796

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings Other Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $27,354 - $12,700
276,332
kWh
$14,654
-
kW-mo/yr
- - - -
02 2.4226: Use / purchase optimum sized compressor $39,016 $7,197 $40,167
873,949
kWh
$(-1,151.0)
-
kW-mo/yr
- - - -
03 2.4239: Eliminate or reduce compressed air usage $28,426 $7,200 $28,426
555,234
kWh
- - - - -
04 2.4133: Use most efficient type of electric motors $94,540 $145,425 $43,894
955,043
kWh
$50,646
-
kW-mo/yr
- - - -
05 2.8227: Adjust / maintain fork lift trucks for most efficient operation $43,460 $174,847 $(-2,204.0)
45,445
kWh
- - $1,316
-
MMBtu
$792
-
MMBtu
$43,556
06 2.3212: Optimize plant power factor $15,371 $63,684 - - $15,371 - - -
TOTAL RECOMMENDED $248,167 $398,353 $122,983
2,706,003
kWh
$64,149
-
kW-mo/yr
$15,371 $1,316
-
MMBtu
$792
-
MMBtu
$43,556
TOTAL IMPLEMENTED $94,796 $14,397 $81,293
1,705,515
kWh
$13,503
-
kW-mo/yr
- - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings Other Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs