Assessment Year | 2022 |
---|---|
Principal Product | Electrical Switchgear |
NAICS | 335313: Switchgear and Switchboard Apparatus Manufacturing |
SIC | 3613: Switchgear and Switchboard Apparatus |
Sales Range | $50 M to 100M |
# of Employees | 92 |
Plant Area |
90,000
ft2
|
Annual Production | 480
units
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $43,209 | 480,462 |
kWh
|
$0.090 | |
Electricity Demand | $12,317 | 1,493 |
kW-mo/yr
|
$8.25 | |
Electricity Fees | $5,627 | - |
|
- | |
Natural Gas | $9,140 | 954 |
MMBtu
|
$9.58 | |
Waste Disposal Costs | |||||
Water Usage | $2,543 | 422 |
Tgal
|
$6.03 | |
Water Disposal | $5,743 | 422 |
Tgal
|
$13.61 | |
TOTAL YEARLY COSTS | $78,579 | ||||
RECOMMENDED SAVINGS* | $124,164 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $84,906 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | By-product Production Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.122: Develop standard procedures to improve internal yields | $73,790 | - | - | - | - | - | - | - | $73,790 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,116 | $120,000 |
$7,307
89,129
kWh
|
$2,498
-
kW-mo/yr
|
$485 | $826 | - | - | - | |
03 | 4.421: Modify current incentive program | $978 | - | - | - | - | - | - | $978 | - | |
04 | 4.231: Purchase equipment instead of leasing | $38,280 | $221,950 | - | - | - | - | $38,280 | - | - | |
TOTAL RECOMMENDED | $124,164 | $341,950 |
$7,307
89,129
kWh
|
$2,498
-
kW-mo/yr
|
$485 | $826 | $38,280 | $978 | $73,790 | ||
TOTAL IMPLEMENTED | $84,906 | $120,000 |
$7,307
89,129
kWh
|
$2,498
-
kW-mo/yr
|
$485 | $826 | - | - | $73,790 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs