Assessment Year | 2013 |
---|---|
Principal Product | Green Stud Lumber |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 103 |
Plant Area |
75,000
ft2
|
Annual Production | 90,000
thousand feet
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $698,998 | 12,453,900 |
kWh
|
$0.056 |
Electricity Demand | $216,818 | 31,402 |
kW-mo/yr
|
$6.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,436 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,614 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4224: Upgrade controls on compressors | $30,841 | $79,939 |
$25,274
456,217
kWh
|
$5,567
-
kW-mo/yr
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $11,184 | $10,125 |
$8,600
155,241
kWh
|
$2,584
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $7,387 | $13,420 |
$5,843
105,470
kWh
|
$1,002
-
kW-mo/yr
|
$540 | $2 | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $4,981 | $4,470 |
$3,262
58,872
kWh
|
$1,719
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,043 | $922 |
$2,043
36,872
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $56,436 | $108,876 |
$45,022
812,672
kWh
|
$10,872
-
kW-mo/yr
|
$540 | $2 | ||
TOTAL IMPLEMENTED | $20,614 | $24,467 |
$16,486
297,583
kWh
|
$3,586
-
kW-mo/yr
|
$540 | $2 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs