| Assessment Year | 2009 |
|---|---|
| Principal Product | Plywood and Veneer |
| NAICS | 321212: Softwood Veneer and Plywood Manufacturing |
| SIC | 2436: Softwood Veneer and Plywood |
| Sales Range | $10 M to 50M |
| # of Employees | 400 |
| Plant Area |
3,600,000
ft2
|
| Annual Production | 45,000,000
thousand feet
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,235,494 | 20,352,900 |
kWh
|
$0.061 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $247,430 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $217,930 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $77,191 | $50,820 |
$77,191
1,482,736
kWh
|
- | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $28,529 | $42,146 |
$28,529
505,090
kWh
|
- | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $29,500 | - |
$29,500
546,000
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $28,320 | $48,980 |
$28,320
456,776
kWh
|
- | |
| 05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $83,890 | $100,800 | - |
$83,890
-
MMBtu
|
|
| TOTAL RECOMMENDED | $247,430 | $242,746 |
$163,540
2,990,602
kWh
|
$83,890
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $217,930 | $242,746 |
$134,040
2,444,602
kWh
|
$83,890
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs